Inspection checklist
Fire safety walk-round
A walk-round of escape routes, fire detection and alarm, fire-fighting equipment and the fire records of a building or department.
Fill it in online - free, no account needed. 20 questions.
What it is for
Walk the escape routes and check the equipment, with every point answered and dated.
- Check escape routes, exits, signs and emergency lighting
- Check alarm points, detectors and extinguishers
- Record what needs fixing, with a date and a name
The full question list
1. Means of Escape
- All fire exits are unobstructed and can be easily opened *
- Fire exit signs are clearly visible and illuminated *
- Escape routes are clear of combustible materials *
- Emergency lighting is operational *
- Fire doors close fully and are not wedged open *
- Assembly points are clearly marked and accessible *
2. Fire Detection & Alarm
- Fire alarm panel shows no faults *
- Manual call points are unobstructed and visible *
- Smoke/heat detectors are free from obstruction *
- Weekly fire alarm test has been completed and recorded *
- Date of last fire alarm test *
3. Fire Fighting Equipment
- Fire extinguishers are in designated positions *
- Extinguisher service dates are current (annual) *
- Pressure gauge shows charged (where applicable) *
- Fire blankets are accessible in kitchen/lab areas *
- Additional observations
4. Documentation & Training
- Fire risk assessment is current (within 12 months) *
- Fire evacuation plan is displayed *
- Fire drill conducted in last 6 months *
- Staff fire training is up to date *
References
- Supports evidence for: Joint Commission International Accreditation Standards for Hospitals, including Standards for Academic Medical Center Hospitals, FMS.06.00 (8th Edition)
AccrediMe is not affiliated with or endorsed by Joint Commission International (JCI). Standard identifiers are cited from JCI's published list; the standards themselves are JCI's and are not reproduced.
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 14(1)
the responsible person must ensure that routes to emergency exits from premises and the exits themselves are kept clear at all times
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 14(2)(f)
emergency doors must not be so locked or fastened that they cannot be easily and immediately opened by any person who may require to use them in an emergency
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 14(2)(h)
emergency routes and exits requiring illumination must be provided with emergency lighting of adequate intensity in the case of failure of their normal lighting
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 14(1)
the responsible person must ensure that routes to emergency exits from premises and the exits themselves are kept clear at all times
Read the source - Supports evidence for: Joint Commission International Accreditation Standards for Hospitals, including Standards for Academic Medical Center Hospitals, FMS.06.01 (8th Edition)
AccrediMe is not affiliated with or endorsed by Joint Commission International (JCI). Standard identifiers are cited from JCI's published list; the standards themselves are JCI's and are not reproduced.
Read the source - Supports evidence for: Joint Commission International Accreditation Standards for Hospitals, including Standards for Academic Medical Center Hospitals, FMS.06.02 (8th Edition)
AccrediMe is not affiliated with or endorsed by Joint Commission International (JCI). Standard identifiers are cited from JCI's published list; the standards themselves are JCI's and are not reproduced.
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 14(2)(g)
emergency routes and exits must be indicated by signs
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 13(1)
the responsible person must ensure that— (a) the premises are, to the extent that it is appropriate, equipped with appropriate fire-fighting equipment and with fire detectors and alarms; and (b) any non-automatic fire-fighting equipment so provided is easily accessible, simple to use and indicated by signs
Read the source - Supports evidence for: The Regulatory Reform (Fire Safety) Order 2005, art. 13(1)
the responsible person must ensure that— (a) the premises are, to the extent that it is appropriate, equipped with appropriate fire-fighting equipment and with fire detectors and alarms; and (b) any non-automatic fire-fighting equipment so provided is easily accessible, simple to use and indicated by signs
Read the source
How the score works
The score is the share of scored questions that pass. N/A is left out of the score; text, dates and signatures are recorded but not scored. A completed template is a record of what you checked; it is not an inspection by a regulator or an accreditation body.